QUEST Central Library Banner

Compressive Strength of Self Compacting Concrete with Partial Replacement of Cement (ME Thesis) (Record no. 62672)

MARC details
000 -LEADER
fixed length control field 02173nam a2200157Ia 4500
100 ## - MAIN ENTRY--AUTHOR NAME
Personal name 16MCE02
100 ## - MAIN ENTRY--AUTHOR NAME
Personal name Ghulam Rasool Siddiqui
-- 16MCE02
-- Supervisor Prof. Dr. Noor Ahmed Memon
245 #0 - TITLE STATEMENT
Title Compressive Strength of Self Compacting Concrete with Partial Replacement of Cement (ME Thesis)
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Name of publisher QUEST
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Year of publication 2018
300 ## - PHYSICAL DESCRIPTION
Number of Pages 48
500 ## - GENERAL NOTE
General note ABSTRACT<br/><br/>The advancement in the construction industry by adopting different techniques and different materials enhanced the performance of concrete is one of the major areas of research in present time. A lot of efforts are made to reduce the construction efforts.<br/>and cost of the concrete. self-Compacting Concrete (SC) is one of types of concrete in which the use of vibrators is eliminated by producing it with substantial.<br/>flow ability that it may fill formwork without any vibration. Thu, reducing the construction effort further the addition of various minerals. industrial and agricultural by-products/materials not only adjust the environmental hazards due to dumping of these materials but reduce the cost of concrete. This study is focused on to investigate the use of Silica Fume (SF) and Fly Ash (FA) together a cement replacement. In this study, SF & FA were used i n combination of 25175, 50150, 75/25 proportion with 5%, I0% and 15% cement replacement respectively. The fresh and hardened properties of SCC were analyzed during the study. For fresh properties, Workability Tests (J-Ring, V Funnel & Slum p Spread) were performed. I n hardened state, compressive strength were checked at 3,7, 14 and 28 days respectively. Also other properties like unit weight and dimensional stability were analyzed. The result revealed significant effect on all the properties studied. However, fresh propert1e of SCC with all replacement levels and combination of SF & FA remained within the range of standard values as per EFNARC 2002. The compressive strength is improved by 17% at 15% replacement level with SF & FA being 50/50 blended together.<br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/> <br/>
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Department of Civil Engineering
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier http://tinyurl.com/3dmwjbu3
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type Thesis and Dissertation
Holdings
Withdrawn status Lost status Home library Current library Date acquired Accession Number Koha item type
    Research Section Research Section 22/10/2018 MP/34-374 Thesis and Dissertation
    Research Section Research Section 26/02/2019 MP/38-415 Thesis and Dissertation

Copyright © 2018,The QUEST, Nawabshah, Shaheed Benazirabad. All rights reserved