Identifcation of Underlynig Causes of Voltage Sag and Swell Disturbances in Power Distribution Network (Record no. 67436)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 01929nam a22001457a 4500 |
| 100 ## - MAIN ENTRY--AUTHOR NAME | |
| Personal name | Asif Ali |
| -- | 17MPE01 |
| -- | Supervisor -Dr. Suhail Khokhar |
| 245 ## - TITLE STATEMENT | |
| Title | Identifcation of Underlynig Causes of Voltage Sag and Swell Disturbances in Power Distribution Network |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT) | |
| Place of publication | Nawabshah |
| Name of publisher | Quest |
| Year of publication | 2021 |
| 300 ## - PHYSICAL DESCRIPTION | |
| Number of Pages | 50p. |
| 500 ## - GENERAL NOTE | |
| General note | <br/><br/><br/>Abstract<br/><br/>A power system is complex system containing four different sections of generation transmission distribution and utilization through which the power is <br/>transmitted from generation side to the consumer side. The power transfer requires equipment and its protection. The efficient power transfer is such that the voltage and<br/>current are free from any types of distortions and at the same time other parameters suggest frequency, power factor, reactive power, apparent power, and so on are maintained. Different types of loads results in distortion of the sinusoidal waves and different factors such as energization of transformers or capacitor banks results in the distortion. Among different voltage issues containing harmonics, transients and interruptions, there are voltage sag and swell that contain reduced level of voltage or high level of voltage. The voltage sag or cells are damageable for the system and equipment respectively both on generation side and consumer side. The research work focuses on characterization of the voltage sags and their impact on the system. The work has been carried out by utilizing Simulink/Matlab and the results have been generated which are discussed for each situation. The results help in obtaining the information about a type of fault occurred on the basis of situation and will be helpful in dealing with that particular issue by taking appropriate step.<br/> |
| 650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical Term | Master of Engineering in Power Engineering |
| 700 ## - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Department of Electrical Engineering |
| 856 ## - ELECTRONIC LOCATION AND ACCESS | |
| Uniform Resource Identifier | https://tinyurl.com/5c2u6ue2 |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Koha item type | Thesis and Dissertation |
| Withdrawn status | Lost status | Home library | Current library | Date acquired | Accession Number | Koha item type |
|---|---|---|---|---|---|---|
| Research Section | Research Section | 13/01/2022 | MP/69-896 | Thesis and Dissertation | ||
| Research Section | Research Section | 13/01/2022 | MP/69-897 | Thesis and Dissertation |