Comparative Assessment of Single Phase Multilevel Cascaded H-Bridge Inverters Using Various Sinusoidal Pulse With Modulation Techniques (ME Thesis) (Record no. 58196)

MARC details
000 -LEADER
fixed length control field 02107nam a2200157Ia 4500
100 ## - MAIN ENTRY--AUTHOR NAME
Personal name Afaque Manzoor
-- 15 MPE 18
-- Supervisor Prof. Dr. Aslam Pervez Memon
245 #0 - TITLE STATEMENT
Title Comparative Assessment of Single Phase Multilevel Cascaded H-Bridge Inverters Using Various Sinusoidal Pulse With Modulation Techniques (ME Thesis)
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Place of publication Nawabshah
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Name of publisher QUEST
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Year of publication 2015
300 ## - PHYSICAL DESCRIPTION
Number of Pages 64
500 ## - GENERAL NOTE
General note ABSTRACT<br/><br/>Inverters have made their significant place in the field of electrical engineering. They have been used in various applications ranging from low power applications to VFDs, STATCOM, (FACTS) devices, Naval Systems and Propulsion Systems. The output of inverter is considered to be the driving force to decide the possible applications where it can be used. The output of inverter has been the main interest for the researchers. The possible outputs can be square wave, quasi square wave and pure sine wave. However Total Harmonic Distortion (THD) puts constraints for square wave and quasi square wave inverters for high power applications. In this thesis, Cascaded H-Bridge Multilevel Inverters (CHB MLI) have be implemented with number of levels starting from five to eleven (5-level, 7-level, 9-level and 11- level). The models have been simulated on SIMULINKIMATLAB. In order to reduce the THD in output voltage and current waveforms, Multicarrier Sinusoidal Pulse Width Modulation (M-SPWM) controlling techniques have been implemented along with each inverter topology. Three techniques such as In Phase Disposition (IPD), Alternate Phase Opposition Disposition (APOD) and Phase Opposition Disposition (POD) have been compared taking THD considerations . From simulation results, it is confirmed that THD is decreased reasonably if higher inverter topologies are considered and POD-SPWM technique when implemented with 11-level CHB MLI, attains very less voltage THD of 10.62% and current THD of 3.7% when an<br/>RL load is used.<br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/>
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Department of Electrical Engineering
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier https://tinyurl.com/6npkwwvp
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type Thesis and Dissertation
Holdings
Withdrawn status Lost status Home library Current library Date acquired Accession Number Koha item type
    Research Section Research Section 27/03/2018 MP/19-192 Thesis and Dissertation
    Research Section Research Section 16/10/2018 MP/32-365 Thesis and Dissertation