QUEST Central Library Banner

Energy Audit & Conservation opportunities In Habib Sugher Mill, Nawabshsh (ME Thesis) (Record no. 55777)

MARC details
000 -LEADER
fixed length control field 02692nam a22001337a 4500
100 ## - MAIN ENTRY--AUTHOR NAME
Personal name Syed, Abdul Malik
-- Supervisor Prof. Dr. Saleem Raza Samo
245 ## - TITLE STATEMENT
Title Energy Audit & Conservation opportunities In Habib Sugher Mill, Nawabshsh (ME Thesis)
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Place of publication Nawabshah:
Name of publisher QUEST,
Year of publication 2014.
300 ## - PHYSICAL DESCRIPTION
Number of Pages 59P, :
500 ## - GENERAL NOTE
General note ABSTRACT<br/><br/>Energy Audit and Conservation are interrelated. They have a major and important role in industries. Due to energy crisis and shortage of energy resources in the country, it is essential to have regular audit activities and conservation measures. The purpose was carried out energy audit in most the crucial section of Habib Sugar Mill, Nawabshah , Sindh Pakistan, In this section energy losses have been determined in Stack flue gas, Blow down, Condensate, Steam on cane% & due Low Steam Bagasse ratio and High Moisture content. The task was done by collection of various data such as flue gas and feed water temperature, the data of cane crushed, sugar production, steam generation and consumption & bagasse consumption on daily basis from the main laboratory and control room of the boiler section. The data was used for calculation of losses and conservation opportunities in the mill. The total losses were Rs.738417000.00 per year. The Stack flue gas losses were 20141062.7GJ &17.4%. In Rs: 24 crore, 78 lacks & 38 thousands per year. Blow down losses were 10982.74 GJ &0.7% In Rs: 1 Crores<br/>& 43 thousands per year. Condensate losses were 33275 GJ & 1.22%. In Rs: 1crore, 75 lacks & 13 thousands per year. Low steam bagasse ratio losses were 155610 ton of steam & 28%.In Rs: 28 Crores, 29 lakhs and 27 thousands. Excess Steam consumption on cane losses were 99052 ton of steam & 18%. In Rs: 18 Crores and 96 thousands. .It was found that by reducing moisture content of bagasse from 50% to 48%,the efficiency of the boilers were increased from 67% to 70%.As a result, amount of Rs:53 Crores could be saved. By adopting energy conservation measures and utilizing energy efficient technologies & using waste heat recovery system, these losses can be reduced and be converted into bagasse saving or electricity generation It is suggested that economizer and air pre heater which are already installed but are not being used for flue gas heat recovery purpose, should be used for saving of fuel and energy. It is crucial to aware the employees and owners of industries by training them through energy audit and energy management techniques to control loss energy waste & by adopting energy conservation measures in the industries.<br/><br/><br/><br/>
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Department of Energy & Environment Engineering
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier http://tiny.cc/jbubvz
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type Thesis and Dissertation
Holdings
Withdrawn status Lost status Home library Current library Date acquired Accession Number Koha item type
    Research Section Research Section 21/11/2016 MP/06-59 Thesis and Dissertation
    Research Section Research Section 25/09/2018 MP/23-240 Thesis and Dissertation
    Research Section Research Section 23/10/2023 MP/79-1089 Thesis and Dissertation

Copyright © 2018,The QUEST, Nawabshah, Shaheed Benazirabad. All rights reserved
Mr. G. Farooq Channar (Librarian) QUEST, Nawabshah, Sindh, Pakistan 67480.
 Ph#: |   0244-9370381-4 Ext. 2308   Email| lib@quest.edu.pk   Web|  http://www.quest.edu.pk