<?xml version="1.0" encoding="UTF-8"?>
<mods xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" version="3.1" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
  <titleInfo>
    <title>Modeling of Factors Influencing Total Harmonic Distortion Due to Personal Computer</title>
  </titleInfo>
  <name type="personal">
    <namePart>Anjum Dehraj  17MPE19 Supervisor-Prof. Dr. Muhammad Usman Keerio</namePart>
    <role>
      <roleTerm authority="marcrelator" type="text">creator</roleTerm>
    </role>
  </name>
  <typeOfResource>text</typeOfResource>
  <originInfo>
    <place>
      <placeTerm type="text">Nawabshah</placeTerm>
    </place>
    <publisher>QUEST</publisher>
    <dateIssued>2020</dateIssued>
    <issuance>monographic</issuance>
  </originInfo>
  <physicalDescription>
    <extent>40p.</extent>
  </physicalDescription>
  <tableOfContents>







ABSTRACT


The penetration of harmonic distortion in electrical power system due to the extensive utilization of nonlinear electronic loads such as Personal Computer (PC) is the root cause of voltage and current distortion and also serious troubles for overall electrical power system. More or less every household consumer  of  electricity  is faced variations in the system voltage, frequency, source impedance. To quantify the influence of above mentioned factors on harmonic distortion magnitudes in nonlinear loads accurately, we need to studies and implement various aspects together with the accurate simulation model of these nonlinear loads. Hence, the objectives of  this paper is first to evaluate the efficiency of developed Simulink model of personal computer for harmonic distortion investigation via comparing with experimental measurement and second is to investigate the influence of above mentioned factors individually and precisely on the total harmonic distortion by using that Simulink model of personal computer. Validation of the PC Simulink model is done by performing experimental  study at Electrical Engineering Department QUEST Nawabshah and comparing the THD and other power quantities obtained from simulation   using      MATLAB      with      the      values   obtained   by   experimental
measurement.


Keywords: Harmonic Distortion, Experimental study, Personal Computer (PC)  , 
Simul ink model , Curve Fitting.
</tableOfContents>
  <subject>
    <topic>Modeling of Factors Influencing Harmonic Distortion Power Engineering  Department of Electrical Engineering</topic>
  </subject>
  <identifier type="uri">http://tinyurl.com/3eacdbzx</identifier>
  <location>
    <url>http://tinyurl.com/3eacdbzx</url>
  </location>
  <recordInfo/>
</mods>