<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>01984nam a22001337a 4500</leader>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">67286</subfield>
    <subfield code="d">67283</subfield>
  </datafield>
  <datafield tag="100" ind1=" " ind2=" ">
    <subfield code="a">Anjum Dehraj </subfield>
    <subfield code="a">17MPE19</subfield>
    <subfield code="a">Supervisor-Prof. Dr. Muhammad Usman Keerio</subfield>
  </datafield>
  <datafield tag="245" ind1=" " ind2=" ">
    <subfield code="a">Modeling of Factors Influencing Total Harmonic Distortion Due to Personal Computer </subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a">Nawabshah</subfield>
    <subfield code="b">QUEST</subfield>
    <subfield code="c">2020</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">40p.</subfield>
  </datafield>
  <datafield tag="505" ind1=" " ind2=" ">
    <subfield code="a">







ABSTRACT


The penetration of harmonic distortion in electrical power system due to the extensive utilization of nonlinear electronic loads such as Personal Computer (PC) is the root cause of voltage and current distortion and also serious troubles for overall electrical power system. More or less every household consumer  of  electricity  is faced variations in the system voltage, frequency, source impedance. To quantify the influence of above mentioned factors on harmonic distortion magnitudes in nonlinear loads accurately, we need to studies and implement various aspects together with the accurate simulation model of these nonlinear loads. Hence, the objectives of  this paper is first to evaluate the efficiency of developed Simulink model of personal computer for harmonic distortion investigation via comparing with experimental measurement and second is to investigate the influence of above mentioned factors individually and precisely on the total harmonic distortion by using that Simulink model of personal computer. Validation of the PC Simulink model is done by performing experimental  study at Electrical Engineering Department QUEST Nawabshah and comparing the THD and other power quantities obtained from simulation   using      MATLAB      with      the      values   obtained   by   experimental
measurement.


Keywords: Harmonic Distortion, Experimental study, Personal Computer (PC)  , 
Simul ink model , Curve Fitting.
</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2=" ">
    <subfield code="a">Modeling of Factors Influencing</subfield>
    <subfield code="a">Harmonic Distortion</subfield>
    <subfield code="a">Power Engineering </subfield>
    <subfield code="a">Department of Electrical Engineering </subfield>
  </datafield>
  <datafield tag="856" ind1=" " ind2=" ">
    <subfield code="u">http://tinyurl.com/3eacdbzx</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="c">THESIS</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="a">RESEARCH</subfield>
    <subfield code="b">RESEARCH</subfield>
    <subfield code="d">2021-08-31</subfield>
    <subfield code="l">0</subfield>
    <subfield code="p">MP/64-823</subfield>
    <subfield code="r">2021-08-31 00:00:00</subfield>
    <subfield code="y">THESIS</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="a">RESEARCH</subfield>
    <subfield code="b">RESEARCH</subfield>
    <subfield code="d">2023-08-17</subfield>
    <subfield code="l">0</subfield>
    <subfield code="p">MP/63-804</subfield>
    <subfield code="r">2023-08-17 00:00:00</subfield>
    <subfield code="w">2023-08-17</subfield>
    <subfield code="y">THESIS</subfield>
  </datafield>
</record>