<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>01635nam a22001457a 4500</leader>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">64761</subfield>
    <subfield code="d">64758</subfield>
  </datafield>
  <datafield tag="082" ind1=" " ind2=" ">
    <subfield code="a">R/IMS-19</subfield>
  </datafield>
  <datafield tag="100" ind1=" " ind2=" ">
    <subfield code="a">Chandio, Murk </subfield>
    <subfield code="a">15MCME05</subfield>
    <subfield code="a">Supervisor - Abdul Aleem Jamali</subfield>
  </datafield>
  <datafield tag="245" ind1=" " ind2=" ">
    <subfield code="a">Plasmonic Antenna for Bioventing Application </subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a">Nawabshah</subfield>
    <subfield code="b">Quest</subfield>
    <subfield code="c">2019</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">36p</subfield>
  </datafield>
  <datafield tag="500" ind1=" " ind2=" ">
    <subfield code="a">ABSTRACT

In the field of medical. diagnosis is the first step to treat any disease. Biosensors detect and analyse the biological and chemical materials that are root cause of abnormalities i n the body . For diagnosis purpose plasmonic biosensor. are widely ed nowadays. Mainly there are two types or plasmonic biosensor &#xB7; which are used for the detection or biological materials: (i) Surface Plasmon Resonance ( .PR) based
biosensor: and (ii) Localized Surface Plasmon Resonance (LSPR ) based bio &#xB7;en or. Each antenna (SPR and LSPR ) has some limitations. which limit  he performance or plasmonic antenna based biosensors. SPR has greater sensitivity than L PR while LSPR is comparatively miniaturized. portable and inexpensive The detection range or LSPR is 0.1-1000 pM under optimal conditions. while. t he detect ion l i m it of . PR is 0.05ng/m L.
I n this work effects of LSPR and SPR sensors arc combined to enhance t he performance characteristics of plasmonic biosensor. The combination or bot h PR and LSPR structures is known as plasmonic perfect absorber ( PPA ). This type or
structure is suitable for t he improvement in performance characteristics of especially sensitivity or plasmonic biosensors.
</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Department of electronic engineering</subfield>
  </datafield>
  <datafield tag="856" ind1=" " ind2=" ">
    <subfield code="u">http://tinyurl.com/23bp2yxh</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="c">THESIS</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="a">RESEARCH</subfield>
    <subfield code="b">RESEARCH</subfield>
    <subfield code="d">2019-07-01</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">R/IMS-19</subfield>
    <subfield code="p">MP/41-456</subfield>
    <subfield code="r">2019-07-01 00:00:00</subfield>
    <subfield code="y">THESIS</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="a">RESEARCH</subfield>
    <subfield code="b">RESEARCH</subfield>
    <subfield code="d">2023-12-13</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">R/IMS-19</subfield>
    <subfield code="p">MP/50-590</subfield>
    <subfield code="r">2023-12-13 00:00:00</subfield>
    <subfield code="w">2023-12-13</subfield>
    <subfield code="y">THESIS</subfield>
  </datafield>
</record>
